This DSINE DN1-250C 200-250A 25 kA 3 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This DSINE DN1-250C 160-200A 25 kA 4 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This DSINE DN2-250D 160-200A 36 kA 3 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This LV525342 200A 36kA 4 Pole EasyPact CVS MCCB from Schneider protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (63A – 630A) than MCB (upto 63A).
This LV525313 250A 25kA 4 Pole EasyPact CVS MCCB from Schneider protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (63A – 630A) than MCB (upto 63A).
This 420239 250A 36kA 3 Pole MCCB from Legrand protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A – 630A) than MCB (upto 63A).
This DSINE DN2-250D 125-160A 36 kA 4 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This DSINE DN2-250N 125-160A 50 kA 3 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This DSINE DN2-250N 160-200A 50 kA 3 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This DSINE DN1-250C 200-250A 25 kA 4 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This DSINE DN2-250D 200-250A 36 kA 3 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This LV525343 250A 36kA 4 Pole EasyPact CVS MCCB from Schneider protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (63A – 630A) than MCB (upto 63A).
This DSINE DN2-250N 100-125A 50 kA 4 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This 420268 200A 50kA 3 Pole MCCB from Legrand protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A – 630A) than MCB (upto 63A).
This 420219 250A 25kA 4 Pole MCCB from Legrand protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A – 630A) than MCB (upto 63A).
This DSINE DN2-250N 200-250A 50 kA 3 Pole MCCB from L&T protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A - 630A) than MCB (upto 63A).
This 420248 200A 36kA 4 Pole MCCB from Legrand protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A – 630A) than MCB (upto 63A).
This 420269 250A 50kA 3 Pole MCCB from Legrand protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (100A – 630A) than MCB (upto 63A).
This LV525457 200A 50kA 4 Pole EasyPact CVS MCCB from Schneider protects electric circuit against overloads and electrical faults. MCCBs cater to higher loads (63A – 630A) than MCB (upto 63A).
MCCB stands for ‘Moulded Case Circuit Breaker’. It is a heavy duty circuit breaker equipped with a tripping coil and can give a signal. The thermal and magnetic elements, adjustable over a wide band, make these MCCB’s ideal for safety and protection of industrial machines and can be installed in Special MCCB DBs. The operating current range of MCCB varies from 16 Amps to 630 Amps. It is mainly used in commercial and industrial applications and in residences it is used at the mains end.